EXL400LED-EXIT: Explosion-Proof LED Evacuation Luminaire
Immediately available
EXL400LED-EXIT: Explosion-Proof LED Evacuation Luminaire
Immediately available
Brand: ATM
IP Rating: IP66IP67
Light Source: LED
Product type: evacuation
The EXL400LED-EXIT is a certified explosion-proof LED evacuation luminaire for Zone 21 & 22 hazardous areas. It offers 3 hours of emergency lighting, robust aluminum construction, and integration with central battery or DALI control systems.
Product information "EXL400LED-EXIT: Explosion-Proof LED Evacuation Luminaire"
Evacuation explosion-proof luminaire with LED modules. Designed for use in zone 21&2,22 of explosion hazard of gases, vapors and mists of flammable liquids with air, as well as flammable dust and fibers. Housing made of aluminum. Standard autonomous power source allowing for min. 3h of lighting of the luminaire. Optional design with adaptation to the central battery ZB or DALI control system. The luminaire has the OBAC 21 ATEX 0060X certificate and CNBOP approval no. 5061/2023
Specification
Category
Parameter
Details
Mechanical Parameters
Body
Anodized aluminum, end caps made of aluminum
Shade
Polycarbonate (PC)
IP Protection Class
IP66, IP67
Protection Class
–
Electrical Parameters
Power (34E)
220-240V, 50-60Hz
Power Supply (35E)
220-240V, 0/50-60Hz
Light Source Type
LED modules
Power Factor
>0.95
Inlet Diameter
Ø20mm (cable Ø6-13mm), Ø25mm (cable Ø9-17mm)
Stuffing Boxes
Plastic, metal
Surge Protection
2kV
Connection Terminal
2.5mm²
Operating Parameters
Lifespan of the Fixture
>70,000 hours (L₈₀B₁₀)
Ambient Temperature
From -40°C to +60°C (depending on the version)
Photometric Parameters
Pictogram Brightness
>200 cd/m²
Dimensions
Frame type
L
L1
H
B
No.
Hp
Libra
EXL400LED-0300-EXIT
524
554
170
145
274
137
~4.5kg
List of Types
Frame type
EX marking
Ambient temperature
during operation [°C]
Ambient temperature
during battery charging [°C]
Power [W]
EXL400LED-…-EXIT
II 3G Ex ec IIC T6 Gc
II 2D Ex tb IIIC T75°C Dc
-20 ÷ +45
0 ÷ +45
14.2
EXL400LED-…-EXIT-ZB
II 3G Ex ec IIC T6 Gc
II 2D Ex tb IIIC T75°C Dc
-40 ÷ +45
not applicable
16.0
EXL400LED-…-EXIT-ZB
II 3G Ex ec IIC T5 Gc
II 2D Ex tb IIIC T100°C Dc
-40 ÷ +55
not applicable
16.0
EXL400LED-…-EXIT-ZB
II 3G Ex ec IIC T5 Gc
II 2D Ex tb IIIC T100°C Dc
-40 ÷ +60
not applicable
16.0
EXL400LED-…-EXIT-DA
II 3G Ex ec IIC T6 Gc
II 2D Ex tb IIIC T75°C Dc
-40 ÷ +45
not applicable
14.2
Luminous flux tolerance: +/- 10%
Power Tolerance: +/- 10%
The parameters in the catalog card are given for Ta=25°C.
The luminous flux, light intensity distribution and light efficiency were tested according to the following standards: