IP Rating: IP65

CRI: >80

Light Source: LED

Product type: evacuation

The TNL300LED evacuation luminaire is tailored for car tunnels, providing clear pictograms for evacuation routes and optional additional lighting. Constructed with powder-coated stainless steel and tempered glass, it ensures durability and CNBOP-certified safety.

Product information "TNL300LED Evacuation Luminaire for Car Tunnels"

  • Type: Evacuation Luminaire with LED Modules
  • Application: Designed for car tunnels
  • Features:
    • Illuminated pictogram indicating the evacuation route
    • Option to integrate additional evacuation route lighting
  • Materials:
    • Housing: Stainless steel with modified powder paint
    • Shade: Tempered glass
  • Approval: CNBOP approval no. 4378/2021

Specification

Parameter Type Specification
Mechanical Parameters
Body Powder-coated stainless steel
Shade Tempered glass
IP Protection Class IP65
Protection Class
Electrical Parameters
Power Supply 35E 230V, 0/50-60Hz
Light Source Type LED modules
Power Factor >0.95
Inlet Diameter Ø20mm (cable Ø6-13mm), Ø25mm (cable Ø9-17mm), Ø32mm (cable Ø13-21mm)
Stuffing Boxes Plastic, metal
Surge Protection 1kV
Connection Terminal 4.0mm²
Operating Parameters
Lifespan of the Fixture >70,000 L₈₀B₁₀
Ambient Temperature From -25°C to +45°C
Photometric Parameters
CRI >80
Pictogram Brightness >200 cd/m²

Dimensions

List of Types

Frame type Luminance [cd/m2] Additional luminous flux [lm] Power [W] Ambient temperature [°C]
TNL300LED-0300-V1 >200 645 18.5 + 8 -25 ÷ +45
TNL300LED-0300-V2 >200 not applicable 18.5 -25 ÷ +45
Luminous flux tolerance: +/- 10%
Power Tolerance: +/- 10%

The parameters in the catalog card are given for Ta=25°C.

The luminous flux, light intensity distribution and light efficiency were tested according to the following standards:

PN-EN ISO/ IEC 17025:2018-02; PN-EN 13032-4+A1:2019-09; PN-EN IEC 60598-1:2021-07; LM-79.

 