Extended Coverage Alarm Terminal (OL-ECAT)

Immediately available

Extended Coverage Alarm Terminal (OL-ECAT)

Immediately available

Brand: Omnileak

Product type: Alarm Units

Extended coverage digital touchscreen leak detection alarm terminal panel with a 12″ LCD, 12 standard relays, 4 addressable circuits, Modbus/TCP & serial, multiple email recipients, SNMP Traps, TCP remote management, and dual power options (100-240VAC or 12-24VDC). Supports up to 4 x 32 cables/modules.

Product information "Extended Coverage Alarm Terminal (OL-ECAT)"

OL-ECAT is a versatile, addressable alarm terminal with a 7″ or 12″ touchscreen, designed for seamless integration with OmniLeak acquisition modules via a proprietary long-range failsafe bus. Housed in an IP54/NEMA 3S water-resistant enclosure, it is ideal for technical rooms with potential water exposure.

  • Monitors up to four circuits (up to 1200m each) for conductive liquids or hydrocarbons
  • Reliable operation with multi-leak detection and redundancy architecture
  • Supports up to 2 km of sensor and jumper cables, with optional loopback wiring for added reliability
  • Intuitive password-protected touchscreen with configurable alarm thresholds
  • High-level integration via Modbus RTU/TCP, email alerts, SNMP Traps, and 12 configurable dry contacts
  • Compatible with various sensor cables for detecting water, acids, hydrocarbons, and more

Designed for robust performance, OL-ECAT ensures precise leak detection with flexible installation options and minimal infrastructure requirements.

Technical data

Specification OL-ECAT7 OL-ECAT12
Display Size & Resolution 7-inch TFT, 800 × 480 12-inch TFT, 1024 × 768
Dimensions (L×W×D) 295 × 260 × 125 mm 400 × 300 × 180 mm
Weight 1.3 kg 7.8 kg
Fire Rating UL94-HB Non-rated (fire-proof steel)
Ingress Rating IP54/NEMA 3S (indoor use only) IP54/NEMA 3S (indoor use only)
Operating Temperature Range 0°C to +55°C 0°C to +55°C
Power Supply Input 100-240VAC or 24VDC (Optional) 100-240VAC or 24VDC (Optional)
Max Length of Cable 2.5 km (Accumulated Sensor & Lead Cables per output) 2.5 km (Accumulated Sensor & Lead Cables per output)
Power Consumption 18.5W max 36W max
Audible Sounder 80dB max, Buzzer with Silence button 80dB max, Buzzer with Silence button
Relay Contact Power Failure + Leak + Cable Break: SPDT (NO/NC) Power Failure + Leak + Cable Break: SPDT (NO/NC)
Relay Switching Voltage SPDT – 0.5 A at 250 VAC, 1A at 30 VDC SPDT – 0.5 A at 250 VAC, 1A at 30 VDC
Relay Switching Power 60W 60W
Supported Protocols (Monitoring) Modbus RS485, Modbus TCP/IP, Bacnet over IP (External Gateway) Modbus RS485, Modbus TCP/IP, Bacnet over IP (External Gateway)
Installation Wall-mounted (Flush mount possible) Wall-mounted (Flush mount possible)

Applications

  • Leak detection in data centers and mission
    critical infrastructure.
  • Banking and commercial Buildings
  • Pump Rooms
  • HVAC Plant rooms
  • Remote chemical facilities
  • Remote chemical facilities
  • Chilled water piping applications
  • Telecom and High-Rise Buildings
  • Stadiums and Museums
  • Tank farms & Airports