Self-Contained Addressable System: This device controls emergency luminaires efficiently, monitoring up to 4096 fittings with continuous parameter downloads. With a built-in rechargeable battery for uninterrupted operation, it offers easy report retrieval and software updates via USB. It ensures seamless communication and integrates with smart building systems for enhanced functionality.
Multifunctional device with touch panel. Controls emergency luminaires. Possibility to download reports on the flash drive and preview the system status through the website.
Monitoring of a configured system with up to 4096 fittings – ideal for medium-sized and large investments.
All parameters of the fittings, the addresses of which are displayed in the control panel, are downloaded by the panel in a continuous manner.
The control unit has a built-in rechargeable battery that allows to monitor the fittings even during a loss of primary power supply.
Possibility to download reports and logs stored in the device’s memory.
Software update via USB port.
Communication between the panel and fittings is carried out by means of the built-in C-BRIDGE 2 signal splitter, through the two-wire TM-Bus communication bus, which does not require polarisation maintenance.
Password protection for different levels of rights.
Cooperation with smart building systems.
Parameter
Max. Number of Emergency Fittings per Channel
64
Max. Number of Communication Channels
4
Max. Number of C-BRIDGE 2 Signal Distributors
16
Max. Number of Emergency Fittings in the System
4096
Material
Powder-coated sheet metal (RAL 9003)
Protection Degree
IP30
Insulation Class
Class I
System components
C-BRIDGE 2
Intermediary device for communication between the controller and DATA 2 series addressable devices. The control panel is equipped with one splitter as a standard, but optionally it is possible to connect a second signal splitter, thus increasing the maximum possible number of luminaires to 4096.
Supply voltage
22-25 V DC
Communication speed
RS-485: 19200 bit/s
Bus voltage
15-25 V
Bus communication speed
5 kbit/s
Insulation class
III
I/O module
Device enabling control of emergency lighting groups, dedicated to DATA 2, DATA 2 RADIO and TM-CB emergency lighting systems. IN input and OUT output models are available. The DATA 2, DATA 2 RADIO and TM-CB system allows the connection of up to 16 I/O modules. The address of each module is set on DiP-switches on their housing. IN SW, IN 24, IN 230 version is used to control the night lighting, fire-emergency lighting groups, fire scenarios and has 8 inputs. The output module (OUT) is used to inform about the system status. It has 8 potential-free outputs.
Wiring
Communication with controller
RS 485 port
Communication with ELVIS, WWW, MODBUS TCP
LAN
Communication with addressable devices
TM-BUS 2-wire data bus (without polarity) – communication cable, for example: YTKSYekw 1 x 2 x 0.8 mm2 or other wires complying with the parameters:
length: max. up to 1,000 m
operating temperature: -15⁰C to + 70⁰C
resistance: max. 75 Ω/km
conductor capacity: max. 120 nF/km
*ELVIS
Emergency Lighting Visualization System
An additional facilitation in the management of emergency lighting luminaires is the software that visualizes the arrangement of luminaires on the actual plan of the building. It enables remote management and testing of emergency lighting fittings, as well as generating and downloading reports required by law.
*optional element of the system
*TM-PROG RFID
TM-PROG RFID is a programming device used to read and addresses of lighting fittings that are compliant with TM-CB A or DATA 2 /DATA 2 EASY system.
» Programming is executed in a wireless mode that provides for operation without connecting lighting fittings to a power supply.
» The programming device has a built-in battery that offers long operating time, and the current consumption is shown on a display.
» The programming device has an ergonomic casing that protects the device against mechanical damage and prevents accidental slipping from the hand.
*optional element of the system
Documents
Datasheet
DATA 2 SELF-CONTAINED ADDRESSABLE SYSTEM