Common data
Rated supply voltage |
220 – 240 V |
AC voltage range |
198 – 264 V |
DC voltage range |
176 – 270 V |
Mains frequency |
0 / 50 / 60 Hz |
Overvoltage protection |
320 V AC, 48 h |
Typ. rated current (at 230 V, 50 Hz, full load) |
112 mA |
Typ. current (220 V, 0 Hz, full load, 100 % dimming level) |
110 mA |
Leakage current (at 230 V, 50 Hz, full load) |
< 0.7 mA |
Typ. input current in no-load operation |
< 25 mA |
In-rush current (peak / duration) |
10 A / 80 µs |
Max. input power |
24.2 W |
Typ. power consumption on stand-by |
< 0.5 W |
Typ. input power in no-load operation |
0.9 W |
Typ. efficiency (at 230 V, 50 Hz, full load) |
83.5 % |
λ over full operating range (max.) |
0.9 C |
λ over full operating range (min.) |
0.3 C |
THD (at 230 V, 50 Hz, full load) |
< 20 % |
Starting time (stand-by) |
< 0.5 s |
Starting time (at 230 V, 50 Hz, full load) |
< 0.66 s |
Starting time (DC mode) |
< 0.4 s |
Switchover time (AC/DC) |
< 0.4 s |
Turn off time (at 230 V, 50 Hz, full load) |
< 0.2 s |
Output current tolerance |
± 5 % |
Max. output current peak (non-repetitive) |
≤ output current + 20 % |
Output LF current ripple (< 120 Hz) |
± 5 % |
Output P_ST_LM (at full load) |
≤ 1 |
Output SVM (at full load) |
≤ 0.4 |
Max. output voltage (U-OUT) |
60 V |
Dimming range |
1 – 100 % (min. 5 mA) |
Mains surge capability (between L – N) |
1 kV |
Mains surge capability (between L/N – PE) |
2 kV |
Surge voltage at output side (against PE) |
3 kV |
Type of protection |
IP20 |
Length |
120 mm |
Width |
51 mm |
Height |
29 mm |
Lifetime |
up to 100000 h |
Guarantee |
5 years |
(1) Valid at 100 % dimming level.
(2) Depending on the selected output current.
(3) Depending on the DALI traffic at the interface.
(4) Valid at 100 % dimming level (for DC the value may differ).
(5) Valid for immediate change of power supply type otherwise the starting time is valid.
(6) Output current is mean value.
(7) For output current range 100 – 250 mA, max. output current peak (non-repetitive) ≤ 250 mA.