CMe3100 M-Bus Metering Gateway for Fixed Network

Immediately available

CMe3100 M-Bus Metering Gateway for Fixed Network

Immediately available

Brand: Elvaco

Product type: M-Bus metering gateways

IP Rating: IP20

Nominal voltage: 100-240 VAC

The CMe3100 is an M-Bus Metering Gateway for Fixed Networks, capable of reading up to 512 meters. It compiles meter data into customized reports and delivers it to receiving systems via fixed networks. Compatible with all M-Bus standard protocol meters and Elvaco’s CMe/CMeX Series, it supports various integration protocols such as ModBus, DLMS, JSON, and REST. With real-time data delivery and flexible licensing, it offers cost-effective customization and functionality extension. Its robust polyamide casing ensures longevity, and it’s easily mountable on a DIN rail. LED indicators provide status updates, and a push button allows for easy device reset.

Product information "CMe3100 M-Bus Metering Gateway for Fixed Network"

The CMe3100 M-Bus Metering Gateway is a first-class solution for remote meter reading. Depending on the product version, the device can read up to 512 meters that use M-Bus standard protocol and can connect to a fixed network, providing a comprehensive meter reading solution. Once recorded, the meter data is compiled in customised reports according to predefined rules and then delivered to a receiving system in real time.

Technical specification

Technical specification M-Bus
Protection class IP20 Interfaces IR, integrated M-Bus Master, M-Bus slave
Dimensions (w x h x d) 72 x 90 x 65 mm (4 DIN modules) M-Bus standard EN 13757
Mounting DIN-rail (DIN 50022) 35 mm Transparent M-Bus TCP/IP and M-Bus 2-wire slave interface
Weight 190 Virtual M-Bus TCP/IP and M-Bus 2-wire slave interface
Decryption Yes
Electrical connections
Supply voltage Screw terminal, cable 0-2,5 mm² Integrated M-Bus Master
M-Bus master port Screw terminal, cable 0,25-1,5 mm² M-Bus baud rate 300 and 2400 bit/s
M-Bus slave port 1 Screw terminal, cable 0,25-1,5 mm² Nominal voltage 28 VDC
M-Bus slave port 2 Screw terminal, cabel 0,25-1,5 mm² Maximum unit loads 32T/48 mA, can be extended with CMeX10-13S
USB master port Type A Maximum numbers of M-Bus devices Software licenses for 8, 32, 64, 128, 256 and 512 devices
USB slave port Type mini B Maximum cable lenghth 1000 m (100 nF/m, maximum 90 W)
Network RJ45 (Ethernet)
General
Electrical characteristics Real time clock accuracy <2 s/day
Nominal voltage 100-240 VAC (±10%) Script engine Intelligent script engine for active content generation
Frequency 50/60 Hz Software update Web interface
Power consumption (max) <15 W Measurement reports HTTP, FTP, SMTP (e-mail)
Power consumption (nom) <5 W Addition Modbus, REST, JSON-RPC, DLMS
Installation category CAT 3 Continuous Readout Mode Modbus, REST
Real time clock backup 24 h
User interface
Green LED Power Datastorage (examples)
Red LED Error 32 meters 15-minute values: ~4 years, Hourly values: >15 years
Yellow LED Status ethernet 128 meters 15-minute values: ~1 year, Hourly values: ~4 years
Push button Factory reset 512 meters 15-minute values: ~3 months, Hourly values: ~1 year
Configuration Web interface (HTTP), Auto configuration (URL), Telnet, REST/JSON
Approvals
EMC EN 61000-6-2, EN 61000-6-3, FCC 47 CFR
Safety EN 62368-1 2018, UL 62368-1:2014 Ed.2], CSA C22.2#62368-1:2014 Ed.2]

Documents

Datasheet
CMe3100 M-Bus Gateway for Fixed Network